Comfort Control has been the reliable company for value cooling and heating in Pendergrass, GA and the surrounding areas since 1992.
Read our reviews from Pendergrass, GA to see how our craftsmanship, professional training and customer service has provided complete satisfaction for our heating and air conditioning services.
Local Reviews
for Pendergrass, GA
PureAirx Stage 1 Filter insatll
VAUGHN - Pendergrass, GA 30567
Great job. On time. Professional.
Great service
VAUGHN - Pendergrass, GA 30567
Fantastic, fast service
Elizabeth - Pendergrass, GA 30567
Everyone was so friendly from the operator to the scheduler and John!
Great service
Nigel - Pendergrass, GA 30567
Great
Choua - Pendergrass, GA 30567
Wonderful. He explained every little detail how it could be fixed
Great
DENNIS - Pendergrass, GA 30567
He is great! Excellent service
Serive on old R22 unit
VAUGHN - Pendergrass, GA 30567
Great took the time to explain how they know how much freon to put in.
Fall check up very through.
VAUGHN - Pendergrass, GA 30567
Great service!
DENNIS - Pendergrass, GA 30567
Professional
Joe - Pendergrass, GA 30567
I would recommend Comfort Control to anyone.
Dennis
DENNIS - Pendergrass, GA 30567
Great
Great Service; saved some money with the coupons
VAUGHN - Pendergrass, GA 30567
Jon explains things very well.
Very happy with Reese
VAUGHN - Pendergrass, GA 30567
He was extremely good at his job and checked everything out !!
Great Service
VAUGHN - Pendergrass, GA 30567
Brian definitely knows what he is doing and he is very friendly also. Great job Brian

james@comfortcontrolinc.com
Maintenance pendergrass. Did a leak search on evaporator coil. Did not find any leaks. Blower wheel is clean. Changed filter. Cleared drain line. Outdoor capacitor is within range. Pressures are within range. System is cooling/heating at this time.
Jordan R.
Ac service in Pendergrass. Replaced variable speed blower motor under full warranty. Also installed surge protection indoor and outdoor under by one get one free per Jeff. System operation normal at this time.
Jordan R.
Ac service in Pendergrass. Discovered failed blower motor. Need to order and return to install.
Eric R.
2 stage 3 ton heat pump system Lifetime outdoor unit replacement compressor warranty. 10 year parts and labor warranty. Replace supply and return plenums. Ducting is currently hard duct and will need to be cut back for sections of flex to reconnect. There is a hole, where the line set goes through the wall, that needs to be sealed up. See pictures. Sections of duct need the insulation reattached or added to.

james@comfortcontrolinc.com
Unable to get financing approved

james@comfortcontrolinc.com
3 Ton AC system with supply and return plenums add 10" return to basement and 8" supply to basement replace disconnect and whip at outdoor unit.

james@comfortcontrolinc.com
No cool in pendergrass Ga, one system. Customer found compressor over heating. Checked all electrical and mechanical components.Found compressor over amping. Found wire damage. And system low on r22 refrigerant. System is 23 years of age , most of the equipment is original. Found evaporator coil to be rusted and corroded and likely to leak refrigerant. Found blow wheel to be dirty likely to slow down air flow. Recommend upgrading to something for efficient and reliable.

Jon F.
Cleared drain line

Jon F.
No cool pendergrass. Found system slightly low on refrigerant. Did leak search on coil found small leak at union for metering device. Tightened union filled system back up with 410a system cooling at this time.

Jon F.
Cooling maintenance pendergrass. Completed maintenance on 6 year old system. Blower and coil are clean. Changed electro static filter. Blower is good on amps. Insulation in attic is good. Temp difference is good. Pressures are good. Outdoor system is clean. Contactor is clean capacitor is good. Amps on motors are good. System cooling at this time.

Jon F.
Heating maintenance pendergrass. Completed maintenance on 5 year old system. Changed filter. Did static pressure test. Air flow is good everywhere except across filter. System needs different filter installed. Recommend electro static filter for optimum air flow and filtration. System has no secondary water safety device to protect system from water damage. Heat strips working good. Blower and evap coil are clean.

james@comfortcontrolinc.com
wanted the system for $4000

Jon F.
Install pendergrass. Completed install of pureairx filter in airhandler. Tested to make sure it came on. System working.

Jon F.
Heating maintenance in pendergrass. Completed heating maintenance. Found all systems working properly. Customer wants electro static filter. Ordered filter will return to install.
Eric R.
$300 tax credit $400 Jackson emc rebate $375 manufacturers rebate

Jon F.
Completed inspection. Found outdoor unit level. All electrical components are good. Amps on motors are good. No overheating. Pressures are good. Indoor system has clean blower and coil. Cleared drain line. System cooling at this time.
Garrett G.
Free consultation

Jon F.
Completed diagnostic found bad capacitor at heat pump. Replaced capacitor. Checked pressures according to target superheat. System cooling at this time. System missing compressor saver and surge protection. Owner is moving in a month. Does not want to do upgrades.
Reece W.
1 system ac tune up complete. Changed filter. Chemically washed condenser coil. Tested mechanical and electrical components. Found system with no water safety and therefore not up to code, recommend adding water safety to protect ceiling from potential water damage. Found blower capacitor to be weak. Found blower wheel to be dirty. Found ductwork to be dirty. Found evaporator coil to be very rusty and corroded and likely to leak. Found black mold in system. Found static pressure to be high at 1.11 in. w.c. When maximum rated static pressure is 0.5 in. w.c. Ductwork is undersized which is the cause of the high static pressure. Refrigerant pressures are as good as they are going to get with airflow not being properly balanced. Due to age and condition of system, recommend upgrading system to a more reliable and more efficient system. Recommend pureairx air purifier to kill mold, bacteria, germs and viruses for improved air quality. System is cooling at this time.

Jon F.
Completed one system maintenance. Found i door unit running very clean inside system. Blower running at good amperage. No restrictions in air flow. Changed filter. Left algae tablets in condensate pump. Cleaned outdoor unit. Pressures are good all electrical components working good. System has no compressor saver or surge protection. Inside system also has no back up water safety.

Jon F.
Completed one system maintenance found indoor with back up water safety and clean blower. Cleared drain line. Filter is new. Wiped everything down with Lysol wipes. Outdoor system has good pressures and all clean and working electrical components. Missing compressor saver and surge protector which will increase life expectancy in system and better protect it as well.
Ta K.
Complete 1 system furnace repair and preventative maintenance check. Found air handler with no power. The breaker is not tripped but nothing operates. Found blown fuse. Put new fuse and system came on the. Runs and blown fuse. Tested all wires and couldn't locate any wiring issue. The system is operating at this time
Ta K.
Complete 1 system furnace repair and preventative maintenance check. We added freon to summer time. Did a leak search at the evaporator coil and did not detect a leak. We will have to double-check pressure summertime for more accurate pressure.System heating at this time

Jon F.
Complete 1 system furnace repair and preventative maintenance check. found no issues. The system is heating properly
Reece W.
Complete 1 system a/c repair and preventative maintenance check. Recharged basement system with 1 lb r22. The system is cooling at this time.