The residents of Jefferson, GA have considered Comfort Control a dependable HVAC company for AC repair and heating services since 1992.
Top Rated HVAC Contractor near Jefferson GA
Read how we provide top quality, 5 Star cooling and heating services and continue to earn five star reviews in the Jefferson, GA area.
Local Reviews
for Jefferson, GA
Very professional
MAX - Jefferson, GA 30549
Jon is always professional and does a great job!!
great service
Bruce - Jefferson, GA 30549
Rick was great. He is a good tech and knows how to service the unit. He was very professional and courteous. He worked very quickly and knew his trade. GREAT JOB.
All around great experience
Brent - Jefferson, GA 30549
Nobody likes replacing their a/c unit but Jeff helped me understand that fixing my old one was only going to be temporary (my system was old). He went through options on units and options on paying for it. Jeff even brought me two window units so we didn’t have to suffer in the heat until our installation date. The two young men that came to do the installation were extremely friendly, professional, and best of all quiet. The job was done before we knew it and our house is cool again. I can not thank them enough for helping us with this and bringing some comfort back to our home.
Great both times he has giving service
WILLIAM - Jefferson, GA 30549
Courteous & Professional
RENEE - Jefferson, GA 30549
Reece was very helpful in solving the issue with our system. Appreciated his expertise and advice.
Prompt, pleasant ,professional and polite. Great price
TIMOTHY - Jefferson, GA 30549
Great service
Oleatha - Jefferson, GA 30549
I was pleased with the professionalism and friendly attitude of the workers at my home. Polite, friendly and caring.
Great service
Oleatha - Jefferson, GA 30549
Reese was polite and carefully explained the issues he found with my system.
Great leadership
Erick - Jefferson, GA 30549
Great leadership and caring about employees leads to great experience! From first contact, to repairs being completed, nothing but great things to say!
great service
Bruce - Jefferson, GA 30549
Jordan was very professional and friendly.
Professional service.
Bruce - Jefferson, GA 30549
Garrett did a great job and worked hard to get us the deal that we could manage.
Competent and thorough
Judy - Jefferson, GA 30549
The technician was amazingly fast arriving and followed through to find the exact problem with the HVAC.
So great!
Randall - Jefferson, GA 30549
He was very prompt, knowledgeable and friendly. Super helpful
Knowledgeable. Quick. Awesome.
Randall - Jefferson, GA 30549
Reece was prompt. Knowledgeable. Kind. Friendly. Very helpful. Awesome.
Great Service
MAX - Jefferson, GA 30549
Jon is very professional and courtesy. He makes sure I understand what he is doing and answers all my questions. He took the time to give me instruction on how to change my electrostatic air filter.

Christian S.
furnace replacement service call. customer's unit was over 10 years old and wasn't working efficiently. Customer had noted high power bills in recent months, moreso than usual. completed furnace installation and ensured proper operation.
Eric R.
16 seer 4 ton heat pump system 10 year parts warranty 10 year labor warranty Lifetime outdoor unit replacement compressor warranty Supply plenum Return plenum Nest thermostat

james@comfortcontrolinc.com
Upstairs 8†actuator is stuck, unhooked 24v and 8†damper is not opening. When system is running off of the upstairs thermostat it is freezing up due to improper airflow throughout the air handler cabinet. Unhooked damper and shook actuator, actuator is opening 80% when shaken. Left actuator unhooked from zone board to allow airflow to the upstairs. Mr. Hewell wants to look into getting actuator replaced after wedding. For now he will leave actuator unhooked and manually open and close when needed.

james@comfortcontrolinc.com
A/c diagnostic in Jefferson. 2 zone system in the attic. System is cooling at this time. Check all operation as of right now everything is wiring properly. Blower wheel is clean, evaporator coil is clean, filter is good. 2 zone dampers are closing and opening as they should. Outdoor condenser looks good, pressure are good.

james@comfortcontrolinc.com
A/c warranty repair in Jefferson. Installed new CoreSense diagnostic. System is cooling at this time.
Jordan R.
warranty coil and TXV. Changed coil, txv and filter drier. Removed all refrigerant from system pulled vacuum and recharged system to 10 degrees subcool. System operation normal at this time.

james@comfortcontrolinc.com
No cool in Jefferson. Found system slightly low on refrigerant. Corrected charge to 10 degrees subcool, and the suction side temperature and pressures continued to fluctuate like the TXV was hunting even though the charge is correct. This is an indication of non-condensables in the refrigerant circuit. As well the fluctuation dipped below 32 and just above 32 while the superheat stayed around the 20-24 degree range. Indoor temp is 72. Outdoor temp 80. Recommend removing all refrigerant, replacing the line drier, and replacing the TXV. Pressure test refrigerant circuit, evacuate to 500, and correct the charge. Check to see if parts are covered under the name Paxton. If they are warranty the evap and TXV.

james@comfortcontrolinc.com
Inspected heat pump system to find it to be slightly low on refrigerant. Mrs. Hansen joined our comfort control membership This will allow us to maintain her system and monitor if the equipment has a leak or was just mischarged.

james@comfortcontrolinc.com
No cool in Jefferson. Found unit low on charge. Added a pound of r22 to correct the charge. Customer does not want to replace at this time. Moving soon.

james@comfortcontrolinc.com
2.5 ton 14 seer heat pump only 10 year parts warranty 2 year labor warranty

james@comfortcontrolinc.com
No cooling call in Jefferson. Arrived to find that upstairs unit compressor has seized. Tried to start it with a new capacitor and hard start kit, but to no avail. Gave options of repair and of replacing. Customer wants to discuss options with his wife.

james@comfortcontrolinc.com
System not cooling. Found failed outdoor unit dual run 40/5 capacitor. Replaced capacitor. Checked refrigerant levels. System was slightly low on refrigerant. Corrected charge with about 8 oz of refrigerant. System is cooling at this time.
Eric R.
3 ton heat pump 16 seer 10 year parts warranty 10 year labor warranty Lifetime outdoor unit replacement compressor warranty Supply plenum with dampers Return plenums High flow registers Nest thermostat Move thermostat to hallway Increase master return to a 10†Increase hallway return to a 12†Replace 10†trunk to living room with a 12†trunk reduced to a short 10â€. Increase 6†in kitchen dining room to 8†fed with the same application as the living room.

james@comfortcontrolinc.com
Replaced blower relay in air handler.

james@comfortcontrolinc.com
A/c diagnostic in Jefferson. Old unit R22 unit was icy up found leak in the evaporator coil. Customer getting new unit.

james@comfortcontrolinc.com
No cooling in Jefferson, GA Heat pump unit freezing up due to no air flow at the indoor unit. Found blower relay meted at the terminals causing no voltage to the blower motor. Relay needs to be replaced and wires repaired. Bypassed relay to run blower constantly, until relay can be replaced. Checked charge on outdoor unit to find it slightly low on refrigerant. Leak searched indoor coil and was not able to find a leak. Possible incorrectly charged from another company. Corrected charge. Will return with the relay to make proper repairs.

Jon F.
Maintenance Jefferson. Checked coils for leaks, found no leaks. Changed filters. Cleared drain lines. Blower fans were clean. Indoor and outdoor capacitors were within range. Pressures were within range. Systems are cooling at this time.

james@comfortcontrolinc.com
Clogged drain line. Cleared line and flushed while under vacuum. Ran for 15 minutes. Line is draining as it should.

james@comfortcontrolinc.com
3 ton outdoor unit heatpump with TXV Indoor unit has been recently replaced. ARUF37B14 10 year parts and labor (add to existing indoor unit as well) 99 year outdoor unit replacement compressor warranty.

james@comfortcontrolinc.com
2 ton heatpump system for the upstairs 10 years parts and labor 99 year outdoor unit replacement compressor warranty.

james@comfortcontrolinc.com
A/c diagnostic in Jefferson. System is cooling at this time. System is in the garage. Condensate pump and tubing was clogged. Flush drain line and cleaned out condensate pump.

james@comfortcontrolinc.com
A/c diagnostic in Jefferson. Found indoor unit running but not the outdoor. Outdoor condenser has a bad control board. System is cooling at this time. But unit is old R22 Nordyne. 2nd unit is in the attic. System is a Gibson R22 from 2006 unit is icing up. Theres a leak in the evaporator coil. No refrigerant in system.
Eric R.
3 ton heat pump and air handler. Lifetime unit replacement compressor warranty. 10 parts and labor warranty.

james@comfortcontrolinc.com
1 system tune up in Jefferson. Checked filter. Checked mechanical and electrical components. Recommend adding overflow protection switch to prevent water damage. Found evaporator coil very rusty and likely to leak. Found blower wheel very dirty, recommend pull and clean service to improve efficiency. Recommend duct cleaning due to condition of return plenum. Found dual capacitor weak(40/5). Recommend compressor saver hard start kit to help extend life of the compressor. System is operating at this time.

Jon F.
Maintenance Jefferson. Completed one system maintenance on 8 year old system. Blower and coil are clean. Changed filter. Cleared drain line. Tested safety switch. Recommend installing inline float switch to main drain line to prevent water damage to the system. Disconnect box is non functional needs a new one. Customer would like quote to have sons room duct and kitchen duct coming straight from plenum by them selves instead of splitting off. Pressures and temp difference are good. System is cooling at this time.