Message To Our Customers Regarding COVID-19

Braselton GA Cooling and Heating

Braselton, GA has turned to Comfort Control since 1992 for professional cooling and heating repairs, installations and maintenance.

Check out these reviews and see how we deliver air conditioning and heating service that residents of Braselton, GA turn to us for again and again.

Local Reviews
for Braselton, GA

Comfort Control Heating & Air Rated 4.9 out of 5 stars based on 46 customer reviews
Mobile Tools for Contractors and Service Professionals Powered by Nearby Now

Map of Braselton, GA

Great Service




Review of Comfort Control Heating & Air

Jon was very knowledgeable and answered all questions.


Map of Braselton, GA

Reece




Review of Comfort Control Heating & Air

I called Comfort Control because I had warm air blowing from my vents. It was late evening on a Friday. They were able to get me in for a Saturday appointment. Reece was the technician who came out. He was prompt to the scheduled appointment time and gave my system a through inspection and gave me some options for the repair. Reece was courteous and professional.


Map of Braselton, GA

Awesome Service




Review of Comfort Control Heating & Air

Excellent service. I have no complaints. Everyone we spoke to was polite and very helpful. I will definitely recommend Comfort Control to others.


Map of Braselton, GA

great




Review of Comfort Control Heating & Air


Map of Braselton, GA

Great job.




Review of Comfort Control Heating & Air


Map of Braselton, GA

Thorough service & terrific rep.!




Review of Comfort Control Heating & Air


Map of Braselton, GA

Great




Review of Comfort Control Heating & Air

Jon Fowler was very professional and answered all of our questions.


Map of Braselton, GA

Great service!




Review of Comfort Control Heating & Air

Performed routine maintenance on HVAC system, Making sure it is in tiptop shape.


Map of Braselton, GA

Great service




Review of Comfort Control Heating & Air

Jon was extremely helpful


Map of Braselton, GA

Pretty fantastic




Review of Comfort Control Heating & Air

This company will stay on the job until it’s perfect


Great Presentation. We will buy from you after we resolve a Roof Replacement Situation.




Review of Comfort Control Heating & Air

Great !!! Wonderful !!!


Great




Review of Comfort Control Heating & Air

Very well. He was knowledgeable and answered all my questions. Good Technician. An asset to your Company


Great service




Review of Comfort Control Heating & Air


Great




Review of Comfort Control Heating & Air

Couldn't have been better


Great Customer Service




Review of Comfort Control Heating & Air

Ta was super friendly and very knowledgeable. He explained every single thing he was doing.


HVAC repair




Review of Comfort Control Heating & Air

Reece did a great job. Very professional. Very friendly.


HVAC repair




Review of Comfort Control Heating & Air


Awesome Customer Service




Review of Comfort Control Heating & Air

Outstanding


Great Service




Review of Comfort Control Heating & Air


Great Service




Review of Comfort Control Heating & Air


Great service




Review of Comfort Control Heating & Air


Very good




Review of Comfort Control Heating & Air


Always Great Service




Review of Comfort Control Heating & Air

I’ve used Comfort Control for 5 years and have never been disappointed. From the first visit to quote a new system, to install, to regular maintenance, to very few service calls they have always been professional and knowledgeable. Work has always been done on time and efficiently. Their employees are the best!


Wonderful




Review of Comfort Control Heating & Air

Perfect...


excellent service




Review of Comfort Control Heating & Air

Ta is very thorough and stops to answer any questions. I would recommend him to anyone needing service.


Reece W.

Reece W.

Ac repair in Braselton. Found crushed return duct and air leakage at supply plenum connection to evaporator coil. Fixed return duct and resealed supply plenum connection.

Near Sahale Falls Dr, Braselton, GA 30517
Jon F.

Jon F.

Ac service braselton. Completed diagnostic. Found leak in evap coil. Blower wheel is dirty. Filter is clean. Outdoor unit has very low pressures. Failing contactor and compressor running with slightly high amps. With age of system and condition.l recommend replacing against repair. Having jim come out to give quotes.

Near Shumard Oak Dr, Braselton, GA 30517
Reece W.

Reece W.

Quoted pricing on a new compressor for upstairs system.

Near Grant Ct, Braselton, GA 30517
Jon F.

Jon F.

Ac service braselton. Completed diagnostic. Found system with bad zone damper to back laundry room. Customer says they don’t use that room. Found zone board in master bedroom closet. Found system with no back up water safety. System is 14 years old. Thermostats are outdated. Outside had compressor terminal ripped off inside unit. Reattached terminal and wires. Capacitor is good and contactor is good. Pressures are good. Compressor running at high amps per manufacturing spec. System will not last very long. Is running and cooling at this time.

Near Northern Oak Dr, Braselton, GA 30517
Jon F.

Jon F.

Ac service braselton. Completed diagnostic. Found system very oversized for area being conditioned. System only servicing front retail back bathroom and back office. System is 5 tons. System should only be 2 tons for that area. System is also leaking refigerant in evap coil upstairs. System is getting severely choked because of the oversize. Condition of system will only get worse if left unchecked. Thermostat controlling system is in back hallway and is mercury thermostat. Customer wants moved to retail area with newer thermostat. Ductwork needs to be sealed to unit upstairs. There is a concerning amount of leakage in ductwork. System has no water safety upstairs. If drain line going outside gets clogged or if system freezes and thaws too quickly it will overflow into attic and cause water damage. Outdoor unit has high amps on compressor and fan motor from the stress of being oversized. Customer needs hard copy mailed to them.

Near Winder Hwy, Braselton, GA 30517
Jon F.

Jon F.

Ac service braselton. Completed diagnostic. Found system with good pressures. Amps on blower and outdoor fan and compressor are good. Both capacitors are good. Filter is a little dirty. Customer is replacing filter. Condensate pump is working. All float switches working. System is cooling properly at this time.

Near Ridgemoor Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed one system maintenance. Found 20 year old system with very dirty blower wheel and concerning amounts of mold. System has weakening capacitor. System also has no secondary water safety device. Outdoor unit has good electrical components and good pressures. Condenser coils have a lot of corrosion. System will need to be replaced soon.

Near Gold Crest Rd, Braselton, GA 30517
Reece W.

Reece W.

No cool upstairs system. Tested system and found the following. Evaporator coil is very rusty and corroded. Blower wheel is dirty. Blower motor capacitor is very weak (5uf). System is low on r22 which means there is a refrigerant leak. Found compressor pulling high amps. Found very weak dual capacitor (45/5). Found electrical pitting present on main electrical switch. Due to age and condition of system, recommend upgrading system to a more reliable and more efficient system. Customer just wants repair for now. Replaced both capacitors in upstairs system and recharged upstairs system. Ductwork is not big enough for that size system so got the pressures as good as I could get them under the circumstances. Customer understands refrigerant will leak back out again and that there is no guarantee on how long refrigerant will last or how long system will last. System is cooling at this time.

Near Loowit Falls Dr, Braselton, GA 30517
Garrett G.

Garrett G.

Free consultation

Near Marsh Creek Ct, Braselton, GA 30517
Jon F.

Jon F.

Completed diagnostic. Found basement system with blower wheel torn apart. Blower motor dead. System is 18 years old running on r22. System needs to be replaced for efficiency. Having Garrett come out to give quote. Upstairs system has failing run capacitor and failing outdoor fan motor. Replaced both. System cooling at this time with 9 degree subcool and 17 degree delta T inside.

Near Marsh Creek Ct, Braselton, GA 30517
Reece W.

Reece W.

Completed install of dehumidifier. Turned on system. System running properly.

Near Ridgemoor Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed inspection. Suggested dehumidifier for basement. Will install dehumidifier tomorrow.

Near Ridgemoor Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed diagnostic. Charged new minisplit to spec. System cooling at this time.

Near Arbor Trce, Braselton, GA 30517
Garrett G.

Garrett G.

Free consultation

Near Honeytree Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed diagnostic. Found upstairs system with clogged drain line and no water safety attached. Cleared drain line. Changed customer provided filter. Evap coil is very rusted and corrosive and currently leaking r22 Freon. Blower wheel is very dirty which decreases the air flow in the house. Run capacitor is very weak and will cause extra stress on the motor which will make it fail prematurely. System has concerning amounts of mold inside and around the system in attic. Outdoor system has low pressures due to leaking in evap coil. Fan motor is good. Compressor is over heating running on higher amps than rated for. Capacitor in outdoor unit is also weak. Trane does not make the evap coil in system anymore and there is no replacement available. System needs to be replaced to fix all problems listed.

Near Honeytree Dr, Braselton, GA 30517
Garrett G.

Garrett G.

Free consultation

Near Silverstone Dr, Braselton, GA 30517
Jon F.

Jon F.

Customer wants quote on replacing mini split system

Near Silverstone Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed one system maintenance. Found drain line clogged tripping the float switch which turned the condenser off. Cleared drain line. Applied pvc glue to drain line and reconnected so that line is sloping down. Blower is clean coil is clean. Outdoor unit has good pressures and clean working electrical components. Cleaned off outdoor unit. System is cooling at this time.

Near Silk Tree Pointe, Braselton, GA 30517
Jon F.

Jon F.

Completed diagnostic. Found drain line clogged. Cleared system. Ran system on cool. System draining properly. Suggested maintenance plan customer will think about it and call is back.

Near Broadmoor Dr, Braselton, GA 30517
Jon F.

Jon F.

Completed one system tune up. Changed filter and made sure system was draining properly. Blower wheel has slight build up of dust but not enough to cause harm to system. Evap coil does have concerning amounts of rust which will start to eat away the copper and eventually cause a leak. System has no back up water safety device to protect system from water damage. System inside also has slight evidence of mold growth inside drain pan which could get into the air flow and cause harm to residents. Suggest installing UV air treatment to kill bacteria allergens and viruses in the air. Outdoor system is clean and has good pressures. All electrical components are good. System missing compressor saver to take load off compressor during start up and allow compressor to live longer.

Near Liberty Ct, Braselton, GA 30517
Christian  S.

Christian S.

(Call back)Arrived on site to find de humidifier not operating due to service code informing us that the filter needs to be washed. I washed the filter and reset the system, unit is now currently functioning at this time.

Near Autumn Flame Dr NE, Braselton, GA 30517
Jon F.

Jon F.

Complete 1 system a/c repair and preventative maintenance check. Found drain pan full of water. Drain line clogged and not slopes properly. Cleared drain line vacuumed the water out of drain pan and re sloped drain line for condensate to drain properly. The system is cooling properly. Customer decline maintenance plan.

Near Ridgemoor Dr, Braselton, GA 30517
Jon F.

Jon F.

A/c repair call. Completed diagnostic on a 10-year-old system. Running on 410 refrigerant. The capacitor is bad. Replaced with a new capacitor. Contactor good amps on both motors within range. Pressures are good. System cooling at this time. The system has no compressor saver or surge protection.

Near Marsh Creek Ct, Braselton, GA 30517
Casey M.

Casey M.

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.

Near Sienna Valley Dr, Braselton, GA 30517
Jon F.

Jon F.

Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.

Near Northern Oak Dr, Braselton, GA 30517