Technician was on time. Called before showing up. After he was finished, the company called to follow up on his visit. Everything went smoothly and the technician was professional.





Christian S.
Warranty in Bethlehem. Arrived on site, found fuse popped in air handler. Replaced with little popper to test unit. Isolators defrost board as intermittent fault. Will need to replace under full warranty due to repairs that have already been made. System is operating at this time, but I left little popper in unit for the customer for the weekend.

Jon F.
Ware Bethlehem. Completed diagnostic. Fuse broken in air handler again. Replaced fuse. System came on and ran and satisfied twice. If problem continues will need to replace thermostat.
Vu T.
No heat in Bethlehem. Check and find d faulty tstat control. Test and find find system operating with no inline water protection and no surge protection. Find heatpump unit have no hard start kit. Replace tstat and install compressor starter kit. System operating at this time. Suggest customer comfort control maintenance plan, system water and surge protection. Suggest pureAireX air purifier system. System operating at this time.

Jon F.
No heat Bethlehem. Completed diagnostic found fuse broken at air handler. Replaced fuse. System running properly. Can not find fault in system if system is running. Contactors inside air handler reading low resistance. Put 5 amp fuse in and it stayed on. If problem occurs again will need to change out contactors.

Jon F.
Warranty Bethlehem. Completed diagnostic. Same issue blowing fuse. Got it working. If problem continues need to replace low voltage wire to outdoor unit.

Jon F.
No heat Bethlehem. Completed diagnostic found wire damaged going into outdoor unit causing fuse to break. Replaced wire. System came on. Heated to 71 to satisfy. System heating properly.
Reece W.
Dropped off two boxes of pureairx filters
Garrett G.
Free consultation for Hvac system Bethlehem Georgia

Jon F.
Ac service Bethlehem. Completed diagnostic. Found bad capacitor at outdoor unit. Replaced capacitor. System cooling. Pressures are good. System is 7 years old and would benefit from having compressor saver and surge protector installed to allow system to live as long as possible. Customer needs hard copy invoice mailed.

Mark S.
On site found tested system found broken low voltage wire going to condenser. Repaired wire system is operating and cooling at this time. Recommend to add secondary back up water safety. Recommend to add surge protection to both units.

Jon F.
Found system slightly overcharged. Reclaimed refrigerant to desired superheat. Delta T in house is good. System cooling.

Jon F.
Completed diagnostic. Found capacitor outside bad. Replaced capacitor. System cooling. Amps are good pressures are good. Signed customer on maintenance. Will return to do maintenance.

Christian S.
(Warranty) I arrived on site, found compressor not running, but fan motor operating. Checked capacitor and found it dead on Herm side, replaced under warranty and unit started operating normally. Checked pressures, unit is operating normally at this time

Christian S.
Arrived on site to preform a one system maintenance. Indoor; checked filter and cleared drain line. Checked electrical connections, amp draw and capacitance, found blower capacitor reading low. Outside; checked coil and refrigerant pressures. Checked electrical connections, amp draw and capacitance. Recommend installing compressor assist kit due to age of system. Unit is operating within manufacture spec at this time.
Garrett G.
Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.
Reece W.
Complete 1 system furnace repair and preventative maintenance check. Installed pureairx electronic filter and signed customer up for one system maintenance plan, will return to do maintenance later.
Vu T.
Complete 1 system a/c repair and preventative maintenance check. Find 2-year-old system in the attic with loose male connection. Replace for the customer. Check and find system operating within manufacturer spec. Close vent to reduce air to the master bedroom. Suggest comfort club membership plan.
Reece W.
Complete 1 system a/c repair and preventative maintenance check. Found system overcharged. Found system with very weak capacitor leaking oil. Found burnt wiring. Found burnt main electrical switch. Found compressor running above maximum rated amperage. Found bad corrosion on condenser coil. Due to age and condition of the system, recommend upgrading system to a more reliable and more efficient system. Balanced refrigerant pressures. Replaced main electrical switch. Replaced capacitor. Current supply temp is 66 degrees. Amp draw on compressor before replacing parts was 22 amps. After replacing them it was 17. Max rated amperage is 16.1. The system is old and worn and may not last very long. The system is cooling at this time.
Reece W.
Complete 1 system a/c repair and preventative maintenance check. Found clogged drain line. Found struggling condensate pump. Rebuilt drain line going to pump and replaced pump as well. System is draining at this time. Customer used $30 coupon

Jon F.
Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.

Jon F.
Complete 1 system a/c repair and preventative maintenance check. Completed diagnostic found blower motor failure. Lennox won't have part until Monday need to schedule Monday to come out and replace the motor.
Steve I.
Complete 1 system a/c repair and preventative maintenance check. Found system low on charge. Weighed in 1.5lbs of R22 in System and was able to get better cooling. The system is old, the customer knows and should be replaced. Customer hopes to have the house sold.
Steve I.
Free consultation for upgrading your system. Thank you for your time. Estimates are valid for 30 days. If you have any questions please contact us at info@comfortcontrolinc.com or call us at (770) 932-5012.

Jon F.
Completed 1 system maintenance found blower wheel dirty and no secondary water safety device. Changed filter. Found pressures good cleared drain line and washed off condenser found outsidesystem running with no surge protection and would benefit from having a compressorsaver installed. Also recommend an ionizer for indoor system to pick any dust that is sitting in the duct work or house to better filter it out of home.
Reece W.
1 system ac pm check completed. Changed filter. Cleared drain line. Added chlorine tablets to evaporater coil drain pan. Found dirty blower wheel, recommend blower wheel pull and clean. Found weak blower capacitor, recommend repair. Chemically washed condenser coil. System is cooling at this time.